River Trace
Any enquiry about River Trace products email to: info_rte@hablem.com
|
|
|
For more information on RTE's products, you can click link below and fill in the form or you can call 603-4106 6048/6049/6050 (Engineering Deparment) for any enquiry. We will reach you later soon. Thank You.
 
Request for RTE's Product Catalogue click here!
|
|
|
|
|
|
|
|
Operation :
The sample enters the cabinet and flows to the sample-conditioning pump, where the sample is prepared for homogenisation. It passes to the RTE designed Mixing Head where final homogenisation occurs. The homogenised sample is then passed to the measuring cell where it is subjected to a beam of infra red light. The light is absorbed and scattered by the sample and the light receivers in the cell collect these signals and pass them to the processing centre where the signals are converted into a PPM reading and displayed on the unit. The signal is also converted to an analogue output signal and passed to the DCS (or similar) system. After measurement the sample is returned to drain. Fresh water can be introduced via a three-way valve to allow periodic checking of the system to ensure that the Zero set point is correct on clean water. If the Zero point is not correct, the operator can reset it.
|

*(click picture to enlarge)
|
Features :
- Low cost
- Compact
- Easy to use
- Low maintenance
- Easy access for servicing
- Sample conditioning system to ensure even particle distribution
- Measurement is temperature compensated
- Automatic cell cleaning function
- Fresh water flushing function
- Measuring ranges 0-50, 0-100, 0-200, 0-500, 0-1000
- 2 x user adjustable alarms
- 1 x fault alarm
- 4-20/0-20 mA output
- Alphanumeric error coding via display
- Built in service aid
- Stainless steel wetted parts as standard (other materials available on request)
- Various power supply options
- Parker or Swagelok pipefittings available
- Suitable for Zone 1 & 2 use
- Non-Hazardous area units also available
- All enclosed in a corrosion resistant weatherproof cabinet
- Optional anti freezing heaters can be supplied
|
|
|
|
|
|
|
|
OCD50 Series Condensate Monitors
|
|
A boiler condensate monitor designed to cater for the special conditions associated with high sample temperatures in condensate applications. This unit will detect oil in much smaller quantities than a conventional observation tank, and so prevent the potential damage to high pressure boilers caused by oil contamination.
|

*(click picture to enlarge)
|
OCD 50M Applications
Boiler Condensate Monitoring
Engine Cooling Water Monitoring
Fresh Water Monitoring
Key features include:
External sample cell to keep high temperatures away from the electronic compartment.
Sensitivity to provide a normal measurement range of 0-10 ppm.
Display resolution of 0.1 ppm.
High temperature optic cell glass and cell seals.
Option of stainless steel wetted parts.
Option of stainless steel housing.
Automatic cell cleaning device.
Germanischer Lloyd approved.
|
|
|
|
|
|
|
|
OCD CW Cooling Water Monitor
|
|
The OCD CW is a low cost solution to simple cooling water monitoring applications. Designed for monitoring engine cooling water and fresh water systems. Boiler condensate can be also monitored with an optional cooler. |
|
OCD CW Cooling Water Monitor Specifications
- Range: 0 - 99 ppm
- Accuracy: +/- 5 ppm
- Concentration indication: 2 x 7 segment LED
- Alarm operating points:1 - 98 ppm (adjustable)
- Alarm 1 operating delay: 0 - 60 second delay (adjustable)
- Alarm 2 operating delay: 10 - 240 second delay (adjustable)
- Alarm contact rating : 8A @ 240V (inductive)
- Alarm relay mode: De-energised in Alarm State
- Zero Oil/Fault Indication: Alphanumeric Code
- Output Signal:
- 0 - 20 mA, 4 - 20 mA (820 min load)
- 0 - 5V & 1 - 5V DC (50K min load)
- where fitted
- Projected Life (Electronics): > 50,000 Hours
- Ambient Temperature: +1C to +55C
- Humidity: 90% RH max @ 55C
- Sample Temperature: + 1°C to + 50°C
- Sample Flow: 0.1 - 2 Litre/Minute
- Sample Pressure: 0.1 to 10 Bar
- Clean Water Requirement: As for Sample
- Weight: 2.25kgs
- Size: 300 x 350 x 73 mm
- Supply Voltage 2 models available: 230V/115V ac and 24V ac
- Supply Variation: ± 10% of Nom. Voltage
- Supply Frequency: 50/60 HZ
- Consumption: 10VA Max Alarm
- 110Vac outlet supply: 220 VA
- Degree of Protection: IP 55
- Electrical installation (over voltage) classification: EN61010-1EC664 category 11
|
|
|
|
|
|
|
See other products:| Bell | Broady | Bronswerk | Carltsoe | Eesiflo | Fluidwell | Hydrotechnik | PCM | Ramco | Sealite | Welker |
|